Genano Nanoparticle Air Purifiers

  • Home
  • Genano Nanoparticle Air Purifiers

Genano Nanoparticle Air Purification Systems

Clinical-Grade Air Decontamination for High-Hygiene Environments

Advanced electronic air decontamination designed specifically for hospitals, clinics, intensive care units, and cleanrooms. Utilizing patented Genano Technology, these units remove even the smallest airborne impurities, including nanoparticles, viruses, bacteria, and toxic gases, down to 0.003 micrometers (3 nm).

Unlike traditional HEPA filters that only trap particles and can clog over time, Genano's cold plasma electrical precipitation method actively eliminates caught microbes, ensuring a constantly sterile, clog-free airflow with zero risk of secondary emissions.

Genano Nanoparticle Air Purifier

Superior Nano-Scale Technology for Air Decontamination

Nano Particle Capture

Removes particulate matter down to nano size.

Pathogen Removal

Removes viruses, bacteria, and molds.

Gas & Odour Elimination

Removes chemical gases and clinical odors.

Plug & Play

Easy plug and play implementation for fast setup.

Filter-Free Design

No disposable filters needed, saving replacement costs.

Easy Maintenance

Automatic self-washing system for effortless upkeep.

✦ Proprietary Patented Technology
✦ Operations in Over 50 Countries
✦ More Than 15,000 Installations
Infection Prevention and Control

"Prevention is better than cure" is a widely recognized proverb that emphasizes the importance of preventing infections to avoid suffering, pain, and financial losses. Infections occur when pathogens like bacteria, viruses, fungi, or parasites invade the body, leading to harm through complex interactions with the immune system.

Organizations like the World Health Organization (WHO) and the Centers for Disease Control and Prevention (CDC) are at the forefront of formulating guidelines for infection prevention and control. Maintaining pure air and clean surfaces is essential for hygienic environments. Alongside standard hygiene practices, modern technologies play a crucial role in reducing infections and protecting vulnerable populations.

For immunocompromised individuals, extra safety measures are vital to mitigate serious health risks. Innovative technologies such as UVC lights, HEPA and ULPA filters, and ionization are being developed and implemented globally to effectively address these challenges. While traditional manual cleaning methods are prone to human error, identifying high-risk areas and applying consistent, purpose-driven technologies can significantly enhance decontamination efforts.

These advanced technologies improve the safety and habitability of indoor spaces, making them infection-free for everyone.

Advantages of Genano Products

  • » Constant CADR 24x7: Maintains consistent clean air delivery rates continuously.
  • » Does Not produce Ozone: Certified safe for standard populated patient environments.
  • » Low Lifetime running costs: No annual replacement filters to purchase.
  • » Compliments existing Ventilation: Integrates easily with central HVAC units.
  • » No Chemical Residues: Operates clean without aerosols or synthetic residues.
  • » No Microbe Growth Substrates: Steel precipitation core deprives bacteria of breeding areas.
  • » Eliminates 99.999% Microbial Pathogens: Highly efficient eradication rate.
  • » Saves Time and Money: Reduces hospital facility maintenance downtime.
  • » Immediate Effects: Rapid commissioning allows for fast ward deployments.
  • » Safeguards Patients & Staff: Provides ultra-clean medical grade environments.

What Genano removes from Air

VIRUSES
BACTERIA
VOC GASES
ODOURS
DNA FRAGMENTS
PRIONS
MOLDS & FUNGI

Target Clinical Applications

Patented air decontamination tailored for critical medical environments.

OT / OR
NICU / SICU
IVF Centres
Isolation Wards
Burns Wards
Ophthalmology OTs
Pathology & Labs
Forensic & Autopsy
Pharma Labs
Cancer Wards
Stem Cell Centres
Dental Clinics
Tuberculosis Wards
Transplant Centres

Create Positive or Negative Air Pressure with Genano 5250i

Or use it as a plug-&-play decontamination unit in any indoor area.

Stand-alone Decontamination Mode
Stand-alone Mode
Standalone Circulation & Clean Air
  • Pathogen Barrier: Prevents transmission of infectious airborne microbes.
  • HAI Prevention: Prevention from surgical site infections & Hospital Acquired Infections (HAIs).
  • Patient Protection: Protects & isolates immunocompromised patients.
  • Hygienic Critical Areas: Raises hospital hygiene in critical areas, i.e. in isolation wards and other protected areas.
Positive Pressure Shield

Creating positive differential pressure prevents pathogens from entering the room. Highly recommended for protecting vulnerable patients during recovery or high-risk treatments.

Typical Applications: Burns Ward, Organ Transplant Rooms, Stemcell Rooms, Cancer Wards, Sickle Cell Wards.
Positive Air Pressure Mode
Positive Pressure Mode
Negative Air Pressure Mode
Negative Pressure Mode
Negative Pressure Isolation

Creating negative pressure prevents air borne pathogens from entering other premises. Essential for isolating contagious conditions and preventing outbreak spread.

Typical Applications: Isolation Wards, Tuberculosis Wards, COVID Wards.
Technical Specifications

According to laboratory standard IEC 61010-1. Certified by CE and CB.

Technical Information Genano 350 Genano 5250i
Clean air delivery rate 50-300 m³/h (boost mode: 395 m³/h) 100-500 m³/h
Particle cleaning efficiency > 99% of 0.1 µm particles 99.5% of particles ≥ 0.003 µm (3 nm)
Microbiological efficacy 99.9% 99.999%
Gas adsorption 600g / 80mm active carbon 1100g / 60mm active carbon
Dimensions (W x H x D) 30 x 90 x 37 cm 60 x 168 x 60 cm
Weight 19 kg 91 kg
Material Aluminium Aluminium, painted steel
Installation Stand-alone with 2 lockable wheels, can be wall-mounted Stand-alone with 4 lockable wheels, can be wall-mounted
Fan speed 10-step speed control 10-step speed control
Power consumption 10-43W (boost mode: 180W) 38-137 W
Sound level 18-44 dB(A) at 3 m (boost mode: 58 dB(A)) 24-53 dB(A) at 3 m
Rated voltage 220-240 Vac 50/60 Hz 220-240 V, 50/60 Hz
Earth Leakage Current IEC 60601-1 Medical Devices -
Operational temperature +5...+40 °C +5...+40 °C
Accessories Wall bracket, insect screen Negative / positive pressure kit, Insect screen